VLS252010CX-100M

TDK · magnetic · case 2.5x2.0

inductance1e-05 (10 µ)
saturation_current0.75 (750 m)
rated_current0.83 (830 m)
dcr0.58 (580 m)
inductance_tol_minus_pct20 (20)
inductance_tol_plus_pct20 (20)
temp_min_c-40 (-40)
temp_max_c105 (105)
device_typeinductor
familyVLS-CX

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 5373 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).

PartManufacturerGradeDirectionFootprint
LQH2HPZ100MJRLMurataminor_reviewupgradefits
DFE252010F-8R2M=P2Murataminor_reviewmixedfits
74405024100Würth Elektronikminor_reviewmixedfits
74405031100Würth Elektronikminor_reviewunknownone_size_larger
78438335100HTWürth Elektronikminor_reviewunknownone_size_larger

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.