| inductance | 4.7e-07 (470 n) |
|---|---|
| saturation_current | 4.4 (4.4) |
| rated_current | 3.5 (3.5) |
| dcr | 0.034 (34 m) |
| device_type | inductor |
| family | SDEM |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 2677 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| DFE201610E-R47M | Murata | drop_in | upgrade | fits |
| TFM201610ALM-R47MTAA | TDK | drop_in | upgrade | fits |
| TFM201612ALMAR47MTAA | TDK | drop_in | upgrade | fits |
| TFM201610ALC-R47MTAA | TDK | drop_in | upgrade | fits |
| TFM201612BLEAR47MTCA | TDK | drop_in | upgrade | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.