TDK · magnetic · case 0805 (2012 Metric)
| inductance | 2.2e-06 (2.2 µ) |
|---|---|
| saturation_current | 0.41029 (410.3 m) |
| saturation_percent_drop | 20 (20) |
| rated_current | 0.8 (800 m) |
| dcr | 0.299 (299 m) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 4656 scored candidates from other manufacturers (catalogue version fd08a0a1c2d511df).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| DFE21CCN2R2MEL | Murata | minor_review | mixed | fits |
| 74479275222 | Würth Elektronik | minor_review | upgrade | fits |
| DFE252008C-2R2M | Murata | minor_review | upgrade | one_size_larger |
| DFE2016CKA-2R2M=P2 | Murata | minor_review | mixed | one_size_larger |
| DFE2016CKA-2R2M | Murata | minor_review | mixed | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.