Würth Elektronik · magnetic · case 7850
| inductance | 2.2e-05 (22 µ) |
|---|---|
| saturation_current | 1.7 (1.7) |
| rated_current | 1.83 (1.83) |
| dcr | 0.103 (103 m) |
| srf | 1.3e+07 (13 M) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| impedance_100mhz | 333 (333) |
| impedance_peak | 23600 (23.6 k) |
| impedance_peak_freq | 1.48e+07 (14.8 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 4411 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| CLF7045NIT-220M-D | TDK | drop_in | unknown | fits |
| CLF7045T-220M-D | TDK | minor_review | unknown | fits |
| SPM6545VC-220M-D | TDK | minor_review | mixed | fits |
| SPM7054VT-220M-D | TDK | minor_review | unknown | fits |
| MDH7045C-220MA | Murata | minor_review | mixed | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.