Würth Elektronik · magnetic · case 2512HT
| inductance | 1e-06 (1000 n) |
|---|---|
| saturation_current | 2.2 (2.2) |
| rated_current | 3.9 (3.9) |
| dcr | 0.0615 (61.5 m) |
| srf | 7.1e+07 (71 M) |
| impedance_100mhz | 625 (625) |
| impedance_peak | 2260 (2.26 k) |
| impedance_peak_freq | 7.07e+07 (70.7 M) |
| device_type | inductor |
| family | WE-MAIA |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3458 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| VLS252012HBX-1R0M-1 | TDK | drop_in | upgrade | fits |
| DFE252012P-1R0M=P2 | Murata | drop_in | upgrade | fits |
| VLS252010ET-1R0N | TDK | drop_in | upgrade | fits |
| VLS252010CX-1R0M-1 | TDK | minor_review | downgrade | fits |
| VLS252012HBX-1R0M | TDK | minor_review | upgrade | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.