Würth Elektronik · magnetic · case 1011
| inductance | 8.2e-06 (8.2 µ) |
|---|---|
| saturation_current | 12.8 (12.8) |
| saturation_percent_drop | 30 (30) |
| rated_current | 7.2 (7.2) |
| dcr | 0.0191 (19.1 m) |
| srf | 3.4e+07 (34 M) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| impedance_100mhz | 556 (556) |
| impedance_peak | 4910 (4.91 k) |
| impedance_peak_freq | 3.37e+07 (33.7 M) |
| temp_min_c | -55 (-55) |
| temp_max_c | 150 (150) |
| device_type | inductor |
| family | WE-CHSA |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 7262 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| MLC1565-922MLC | Coilcraft | minor_review | mixed | one_size_larger |
| XAL1510-682MED | Coilcraft | major_review | mixed | one_size_larger |
| XAL1510-822MED | Coilcraft | major_review | mixed | one_size_larger |
| XAL1010-822MED | Coilcraft | major_review | mixed | one_size_larger |
| SPM10065VT-6R8M-D | TDK | minor_review | mixed | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.