Würth Elektronik · magnetic · case 1011
| inductance | 5.6e-06 (5.6 µ) |
|---|---|
| saturation_current | 14.9 (14.9) |
| saturation_percent_drop | 30 (30) |
| rated_current | 9.2 (9.2) |
| dcr | 0.013 (13 m) |
| srf | 4.1e+07 (41 M) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| impedance_100mhz | 620 (620) |
| impedance_peak | 3690 (3.69 k) |
| impedance_peak_freq | 4.01e+07 (40.1 M) |
| temp_min_c | -55 (-55) |
| temp_max_c | 150 (150) |
| device_type | inductor |
| family | WE-CHSA |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 7155 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| MPGV1D1054L4R7 | KEMET | minor_review | downgrade | fits |
| MPXV1D1054L4R7 | KEMET | minor_review | downgrade | fits |
| XAL1010-472MED | Coilcraft | major_review | mixed | fits |
| XAL1010-562MED | Coilcraft | major_review | mixed | one_size_larger |
| MLC1565-602MLC | Coilcraft | minor_review | mixed | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.