Würth Elektronik · magnetic · case 1212
| inductance | 1e-06 (1000 n) |
|---|---|
| saturation_current | 33.7 (33.7) |
| saturation_percent_drop | 30 (30) |
| rated_current | 22.5 (22.5) |
| dcr | 0.0024 (2.4 m) |
| srf | 8.10723e+07 (81.07 M) |
| impedance_100mhz | 449 (449) |
| impedance_peak | 483 (483) |
| impedance_peak_freq | 8.11e+07 (81.1 M) |
| temp_min_c | -55 (-55) |
| temp_max_c | 150 (150) |
| device_type | inductor |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 4899 scored candidates from other manufacturers (catalogue version 7745e7dd59dce573).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SPM12565VT-1R0M-D | TDK | minor_review | mixed | one_size_larger |
| XAL1010-102MED | Coilcraft | major_review | mixed | fits |
| PCM120T-1R0N-D | TDK | minor_review | unknown | one_size_larger |
| SPM10065VC-1R0M-D | TDK | minor_review | mixed | smaller |
| PCM120T-1R2N-D | TDK | minor_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.