Würth Elektronik · magnetic · case 1014
| inductance | 0.0033 (3.3 m) |
|---|---|
| saturation_current | 0.5 (500 m) |
| saturation_percent_drop | 10 (10) |
| rated_current | 0.35 (350 m) |
| dcr | 4 (4) |
| srf | 755000 (755 k) |
| impedance_100mhz | 115 (115) |
| impedance_peak | 266000 (266 k) |
| impedance_peak_freq | 752000 (752 k) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-TI HV |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 496 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| MSS1210-335KED | Coilcraft | minor_review | mixed | one_size_larger |
| APCI00121280282M80 | Pulse Electronics | minor_review | unknown | one_size_larger |
| RFS1317-335KL | Coilcraft | minor_review | unknown | one_size_larger |
| MSS1210-275KED | Coilcraft | minor_review | mixed | one_size_larger |
| AIUR-06-332J | Abracon | minor_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.