Würth Elektronik · magnetic · case RM10
| inductance | 0.0005 (500 µ) |
|---|---|
| saturation_current | 4 (4) |
| saturation_percent_drop | 20 (20) |
| rated_current | 0.6 (600 m) |
| dcr | 0.18 (180 m) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PFC |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 1518 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| ATCA-06-501M-H | Abracon | major_review | mixed | different_case |
| ATCA-06-501M-V | Abracon | major_review | mixed | different_case |
| ATCA-08-471M-H | Abracon | major_review | mixed | different_case |
| ATCA-08-471M-V | Abracon | major_review | mixed | different_case |
| AGP4233-474ME | Coilcraft | minor_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.