| inductance | 3.3e-05 (33 µ) |
|---|---|
| saturation_current | 2.8 (2.8) |
| saturation_percent_drop | 10 (10) |
| rated_current | 1.2 (1.2) |
| dcr | 0.17 (170 m) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-DD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3686 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SPM10065VC-330M-D | TDK | minor_review | upgrade | smaller |
| SRR1205-330ML | Bourns | minor_review | unknown | one_size_larger |
| LSRNJ12555GL330MMY | Taiyo Yuden | minor_review | unknown | one_size_larger |
| LCRNJ12555GL330MN | Taiyo Yuden | minor_review | unknown | one_size_larger |
| LCRNJ12555GL330MN00J | Taiyo Yuden | minor_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.