Würth Elektronik · magnetic · case 6050
| inductance | 1e-05 (10 µ) |
|---|---|
| saturation_current | 1.8 (1.8) |
| saturation_percent_drop | 10 (10) |
| rated_current | 2.1 (2.1) |
| dcr | 0.088 (88 m) |
| srf | 4e+07 (40 M) |
| impedance_100mhz | 713 (713) |
| impedance_peak | 10500 (10.5 k) |
| impedance_peak_freq | 3.43e+07 (34.3 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 5467 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| CLF6045NIT-100M-D | TDK | drop_in | unknown | fits |
| VLS6045EX-100M-H | TDK | drop_in | mixed | fits |
| CLF6045T-100M-D | TDK | minor_review | unknown | fits |
| B82471A1103M000 | TDK | minor_review | mixed | fits |
| B82472G6103M000 | TDK | minor_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.