Würth Elektronik · magnetic · case 5848
| inductance | 3.3e-05 (33 µ) |
|---|---|
| saturation_current | 1.17 (1.17) |
| saturation_percent_drop | 10 (10) |
| rated_current | 1.09 (1.09) |
| dcr | 0.23 (230 m) |
| srf | 1.4e+07 (14 M) |
| impedance_100mhz | 427 (427) |
| impedance_peak | 38200 (38.2 k) |
| impedance_peak_freq | 1.45e+07 (14.5 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3686 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| B82472G6333M000 | TDK | minor_review | mixed | one_size_larger |
| 1255AY-330M | Murata | minor_review | mixed | one_size_larger |
| VLS6045EX-330M-H | TDK | minor_review | mixed | one_size_larger |
| 1273AS-H-330M | Murata | major_review | unknown | one_size_larger |
| B82472P6333M000 | TDK | minor_review | mixed | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.