Würth Elektronik · magnetic · case 1280P
| inductance | 1.5e-06 (1.5 µ) |
|---|---|
| saturation_current | 24 (24) |
| saturation_percent_drop | 10 (10) |
| rated_current | 12 (12) |
| dcr | 0.0055 (5.5 m) |
| srf | 4.92e+07 (49.2 M) |
| impedance_100mhz | 246 (246) |
| impedance_peak | 743 (743) |
| impedance_peak_freq | 4.92e+07 (49.2 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 150 (150) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3451 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| B82559B3152A016 | TDK | minor_review | unknown | one_size_larger |
| PCM120T-1R5N-D | TDK | minor_review | unknown | one_size_larger |
| MPGV1D1054L1R5 | KEMET | minor_review | unknown | smaller |
| B82559A3152A016 | TDK | major_review | unknown | one_size_larger |
| XAL1580-132MED | Coilcraft | major_review | mixed | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.