744770112

Würth Elektronik · magnetic · case 1280

inductance1.2e-05 (12 µ)
saturation_current6.5 (6.5)
saturation_percent_drop10 (10)
rated_current6.2 (6.2)
dcr0.021 (21 m)
srf1.6e+07 (16 M)
impedance_100mhz253 (253)
impedance_peak9110 (9.11 k)
impedance_peak_freq2.05e+07 (20.5 M)
temp_min_c-40 (-40)
temp_max_c125 (125)
device_typeinductor
familyWE-PD

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 6754 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).

PartManufacturerGradeDirectionFootprint
SLF12565T-100MTDKminor_reviewunknownone_size_larger
SRR1280-100MBournsminor_reviewmixedone_size_larger
SPM10065VC-100M-DTDKminor_reviewmixedsmaller
SLF12565T-150MTDKminor_reviewmixedone_size_larger
SLF10145T-100MTDKminor_reviewmixedsmaller

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.