Würth Elektronik · magnetic · case 1014
| inductance | 0.0001 (100 µ) |
|---|---|
| saturation_current | 2.8 (2.8) |
| saturation_percent_drop | 10 (10) |
| rated_current | 2.4 (2.4) |
| dcr | 0.125 (125 m) |
| srf | 4.49171e+06 (4.492 M) |
| impedance_100mhz | 117 (117) |
| impedance_peak | 76300 (76.3 k) |
| impedance_peak_freq | 4.5e+06 (4.5 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3312 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| B82477R4104M100 | TDK | minor_review | mixed | one_size_larger |
| SLF10145T-101M | TDK | major_review | downgrade | fits |
| B82477P4104M000 | TDK | minor_review | mixed | one_size_larger |
| SLF12565T-101M | TDK | minor_review | mixed | one_size_larger |
| MSS1583-104KED | Coilcraft | major_review | unknown | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.