Würth Elektronik · magnetic · case 8055
| inductance | 0.0001 (100 µ) |
|---|---|
| saturation_current | 1.2 (1.2) |
| saturation_percent_drop | 10 (10) |
| rated_current | 1.1 (1.1) |
| dcr | 1 (1) |
| srf | 9.51938e+06 (9.519 M) |
| impedance_100mhz | 549 (549) |
| impedance_peak | 72000 (72 k) |
| impedance_peak_freq | 9.6e+06 (9.6 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-PD |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3312 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| 1267AY-101M=P3 | Murata | minor_review | mixed | fits |
| 1267AY-101M | Murata | drop_in | mixed | fits |
| SPM7054VC-101M-D | TDK | drop_in | mixed | fits |
| SPM7054VT-101M-D | TDK | minor_review | unknown | fits |
| VLS6045EX-101M-H | TDK | minor_review | mixed | smaller |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.