Würth Elektronik · magnetic · case 2512
| inductance | 3.3e-07 (330 n) |
|---|---|
| saturation_current | 4.1 (4.1) |
| saturation_percent_drop | 10 (10) |
| rated_current | 6.18 (6.18) |
| dcr | 0.0267 (26.7 m) |
| srf | 1.74e+08 (174 M) |
| impedance_100mhz | 250 (250) |
| impedance_peak | 713 (713) |
| impedance_peak_freq | 1.73e+08 (173 M) |
| temp_min_c | -55 (-55) |
| temp_max_c | 150 (150) |
| device_type | inductor |
| family | WE-MAPI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3102 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| TFM252012ALMAR33MTAA | TDK | drop_in | mixed | fits |
| TFM322512ALMAR33MTAA | TDK | minor_review | mixed | different_case |
| TMS252012ALM-R33MTAA | TDK | major_review | mixed | fits |
| LCENA2520MKTR33M0TK | Taiyo Yuden | major_review | mixed | fits |
| LCENA2520MKTR33M0TKJ | Taiyo Yuden | major_review | mixed | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.