Würth Elektronik · magnetic · case 1365
| inductance | 9.2e-06 (9.2 µ) |
|---|---|
| saturation_current | 10.5 (10.5) |
| rated_current | 14.4 (14.4) |
| dcr | 0.00836 (8.36 m) |
| srf | 2.4e+07 (24 M) |
| impedance_100mhz | 251 (251) |
| impedance_peak | 2660 (2.66 k) |
| impedance_peak_freq | 2.05e+07 (20.5 M) |
| device_type | inductor |
| family | WE-HCI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3326 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| CLF10040-10N | TDK | minor_review | upgrade | smaller |
| CLF12577-10N | TDK | minor_review | upgrade | smaller |
| MPX1D1250L100 | KEMET | major_review | mixed | fits |
| CLF7045-10N | TDK | minor_review | upgrade | smaller |
| SPM12565VT-100M-D | TDK | major_review | mixed | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.