7443551600

Würth Elektronik · magnetic · case 1365

inductance6e-06 (6 µ)
saturation_current14 (14)
rated_current13.6 (13.6)
dcr0.00913 (9.13 m)
srf2.2e+07 (22 M)
impedance_100mhz433 (433)
impedance_peak6670 (6.67 k)
impedance_peak_freq3.2e+07 (32 M)
temp_min_c-40 (-40)
temp_max_c155 (155)
device_typeinductor
familyWE-HCI

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 4034 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).

PartManufacturerGradeDirectionFootprint
PCM120T-6R8M-DTDKminor_reviewunknownfits
SPM12565VT-6R8M-DTDKminor_reviewmixedfits
SPM12565VC-6R8M-DTDKminor_reviewmixedfits
XAL1510-682MEDCoilcraftminor_reviewunknownone_size_larger
SPM7054VC-6R8M-DTDKmajor_reviewmixedsmaller

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.