Würth Elektronik · magnetic · case 1365
| inductance | 4.7e-07 (470 n) |
|---|---|
| saturation_current | 50 (50) |
| rated_current | 54.9 (54.9) |
| dcr | 0.000704 (704 µ) |
| srf | 1e+08 (100 M) |
| impedance_100mhz | 598 (598) |
| impedance_peak | 706 (706) |
| impedance_peak_freq | 1.16e+08 (116 M) |
| device_type | inductor |
| family | WE-HCI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 2606 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| PCM120T-R50N-D | TDK | major_review | mixed | fits |
| PCM120T-R40N-D | TDK | major_review | mixed | fits |
| MPGV1D1054LR47 | KEMET | major_review | downgrade | smaller |
| XAL1580-401ME | Coilcraft | minor_review | upgrade | one_size_larger |
| SER2010-501MLD | Coilcraft | major_review | downgrade | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.