Würth Elektronik · magnetic · case 1350
| inductance | 9e-07 (900 n) |
|---|---|
| saturation_current | 28 (28) |
| rated_current | 36 (36) |
| dcr | 0.001782 (1.782 m) |
| srf | 7.2e+07 (72 M) |
| impedance_100mhz | 803 (803) |
| impedance_peak | 1140 (1.14 k) |
| impedance_peak_freq | 8.11e+07 (81.1 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 155 (155) |
| device_type | inductor |
| family | WE-HCI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 4153 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| PCM120T-R82N-D | TDK | minor_review | unknown | fits |
| PCM120T-1R0N-D | TDK | minor_review | unknown | fits |
| SPM12565VC-1R0M-D | TDK | major_review | mixed | fits |
| SPM12565VT-1R0M-D | TDK | major_review | mixed | fits |
| SPM10065VC-1R0M-D | TDK | major_review | mixed | smaller |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.