Würth Elektronik · magnetic · case 1350
| inductance | 1e-05 (10 µ) |
|---|---|
| saturation_current | 5 (5) |
| rated_current | 11.1 (11.1) |
| dcr | 0.01551 (15.51 m) |
| srf | 1.6e+07 (16 M) |
| impedance_100mhz | 176 (176) |
| impedance_peak | 2280 (2.28 k) |
| impedance_peak_freq | 1.64e+07 (16.4 M) |
| device_type | inductor |
| family | WE-HCI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3836 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| CLF6045-10N | TDK | minor_review | upgrade | smaller |
| CLF7045-10N | TDK | minor_review | upgrade | smaller |
| CLF10040-10N | TDK | minor_review | upgrade | smaller |
| CLF12577-10N | TDK | minor_review | upgrade | smaller |
| VLS6045-10N | TDK | minor_review | mixed | smaller |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.