Würth Elektronik · magnetic · case 1210
| inductance | 4.7e-07 (470 n) |
|---|---|
| saturation_current | 44.4 (44.4) |
| saturation_percent_drop | 10 (10) |
| rated_current | 40.2 (40.2) |
| dcr | 0.00185 (1.85 m) |
| srf | 1.4e+08 (140 M) |
| inductance_tol_minus_pct | 20 (20) |
| inductance_tol_plus_pct | 20 (20) |
| impedance_100mhz | 167 (167) |
| impedance_peak | 167 (167) |
| impedance_peak_freq | 9.47e+07 (94.7 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-HCC |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3688 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| PCM120T-R50N-D | TDK | minor_review | mixed | one_size_larger |
| MPGV1D1054LR47 | KEMET | minor_review | downgrade | fits |
| PCM120T-R40N-D | TDK | minor_review | mixed | one_size_larger |
| XAL1580-401MED | Coilcraft | major_review | mixed | one_size_larger |
| B82559A1042A025 | TDK | redesign | unknown | overflows |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.