Würth Elektronik · magnetic · case 7040
| inductance | 3.3e-06 (3.3 µ) |
|---|---|
| saturation_current | 11 (11) |
| rated_current | 8.1 (8.1) |
| dcr | 0.01892 (18.92 m) |
| srf | 4.3e+07 (43 M) |
| impedance_100mhz | 1300 (1.3 k) |
| impedance_peak | 2460 (2.46 k) |
| impedance_peak_freq | 6.37e+07 (63.7 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 150 (150) |
| device_type | inductor |
| family | WE-HCI |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 4518 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SPM6545VT-3R3M-D | TDK | drop_in | unknown | fits |
| SPM7054VC-3R3M-D | TDK | minor_review | unknown | one_size_larger |
| SPM6545VC-3R3M-D | TDK | minor_review | unknown | fits |
| SPM10065VC-3R3M-D | TDK | major_review | unknown | one_size_larger |
| SPM6550T-3R3M-HZR | TDK | major_review | mixed | fits |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.