Würth Elektronik · magnetic · case 1088
| inductance | 1.5e-07 (150 n) |
|---|---|
| saturation_current | 85 (85) |
| saturation_percent_drop | 30 (30) |
| rated_current | 83 (83) |
| dcr | 0.0001197 (119.7 µ) |
| srf | 4.1e+07 (41 M) |
| impedance_100mhz | 16.5 (16.5) |
| impedance_peak | 29.5 (29.5) |
| impedance_peak_freq | 4.01e+07 (40.1 M) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | inductor |
| family | WE-HCM |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3269 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SLC1480-151MLD | Coilcraft | major_review | mixed | one_size_larger |
| VLBU1007090T-R15L | TDK | major_review | mixed | fits |
| SLR7010-151KED | Coilcraft | major_review | mixed | fits |
| SLC1480-171MLD | Coilcraft | major_review | mixed | one_size_larger |
| SLC1480-131MLD | Coilcraft | major_review | mixed | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.