7443082012B

Würth Elektronik · magnetic · case 1088

inductance1.2e-07 (120 n)
saturation_current111 (111)
rated_current83 (83)
dcr0.0001197 (119.7 µ)
srf5.8e+07 (58 M)
impedance_100mhz22.9 (22.9)
impedance_peak30 (30)
impedance_peak_freq5.46e+07 (54.6 M)
device_typeinductor
familyWE-HCM

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 2499 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).

PartManufacturerGradeDirectionFootprint
VLBU10060120T-R12LTDKminor_reviewmixedsmaller
VLBU10060120R12LF4TDKminor_reviewmixedsmaller
VLBUC12060110R12LF4TDKminor_reviewmixedone_size_larger
VLBUC12060120R12LF3TDKminor_reviewmixedone_size_larger
VLBUC12060120R12LF4TDKminor_reviewmixedone_size_larger

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.