Würth Elektronik · magnetic · case 1190
| inductance | 3.3e-07 (330 n) |
|---|---|
| saturation_current | 44.9 (44.9) |
| rated_current | 56 (56) |
| dcr | 0.000321 (321 µ) |
| srf | 2.4e+07 (24 M) |
| impedance_100mhz | 14.7 (14.7) |
| impedance_peak | 43.7 (43.7) |
| impedance_peak_freq | 2.31e+07 (23.1 M) |
| device_type | inductor |
| family | WE-HCM |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 2185 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SLC1480-321 | Coilcraft | minor_review | upgrade | one_size_larger |
| SLC1480-301 | Coilcraft | minor_review | upgrade | one_size_larger |
| SLR1190-311 | Coilcraft | major_review | mixed | fits |
| SLR1190-371 | Coilcraft | major_review | mixed | fits |
| SLR1075-271 | Coilcraft | minor_review | mixed | smaller |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.