744290130

Würth Elektronik · magnetic · case 1712

inductance1.3e-05 (13 µ)
saturation_current10 (10)
rated_current10 (10)
dcr0.0027 (2.7 m)
inductance_tol_minus_pct30 (30)
inductance_tol_plus_pct30 (30)
impedance_100mhz52.61 (52.61)
impedance_peak132.81 (132.8)
impedance_peak_freq8.7096e+08 (871 M)
dm_impedance_100mhz30.067 (30.07)
temp_min_c-40 (-40)
temp_max_c125 (125)
device_typecommonModeChoke
familyWE-UCF

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 21 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).

PartManufacturerGradeDirectionFootprint
DLW43SH110XK2Muratano_substituteunknown
PLT10HH9016R0PNMuratano_substituteunknown
DLW32SH110XK2Muratano_substituteunknown
SNT-S30TFKEMETno_substituteunknown
SNT-S30TKEMETno_substituteunknown

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.