Würth Elektronik · magnetic · case 1211
| inductance | 9e-06 (9 µ) |
|---|---|
| saturation_current | 8 (8) |
| rated_current | 8 (8) |
| dcr | 0.006 (6 m) |
| inductance_tol_minus_pct | 30 (30) |
| inductance_tol_plus_pct | 30 (30) |
| impedance_100mhz | 711.55 (711.5) |
| dm_impedance_100mhz | 263.53 (263.5) |
| dm_impedance_peak | 2785 (2.785 k) |
| dm_impedance_peak_freq | 1.0701e+09 (1.07 G) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | commonModeChoke |
| family | WE-CMDC |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 46 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| SN16P-130 | KEMET | redesign | unknown | overflows |
| ACM12V-701-2PL-TL05 | TDK | no_substitute | unknown | |
| SRF4532TA-282Y | Bourns | no_substitute | unknown | |
| SRF3225TP-102Y | Bourns | no_substitute | unknown | |
| PLT10HH8016R0PN | Murata | no_substitute | unknown |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.