Würth Elektronik · magnetic · case 1206
| inductance | 2.578e-06 (2.578 µ) |
|---|---|
| rated_current | 0.2 (200 m) |
| dcr | 1.2 (1.2) |
| inductance_tol_minus_pct | 30 (30) |
| inductance_tol_plus_pct | 30 (30) |
| impedance_100mhz | 2157.8 (2.158 k) |
| impedance_peak | 4709.9 (4.71 k) |
| impedance_peak_freq | 4.6259e+08 (462.6 M) |
| dm_impedance_100mhz | 30.297 (30.3) |
| dm_impedance_peak | 136.4 (136.4) |
| dm_impedance_peak_freq | 2.6124e+09 (2.612 G) |
| temp_min_c | -40 (-40) |
| temp_max_c | 125 (125) |
| device_type | commonModeChoke |
| family | WE-CNSW |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 16 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
This part's own record is incomplete, so no substitute is graded recommended.
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| PA4339.301NLT | Pulse Electronics | redesign | unknown | overflows |
| SN3-100 | KEMET | redesign | mixed | overflows |
| ACM12V-351-2PL-TL00 | TDK | redesign | unknown | overflows |
| SNT-D10T | KEMET | redesign | mixed | overflows |
| SNT-D10 | KEMET | redesign | mixed | overflows |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.