74404052010

Würth Elektronik · magnetic · case 5020

inductance1e-06 (1000 n)
saturation_current6.3 (6.3)
saturation_percent_drop30 (30)
rated_current3.9 (3.9)
dcr0.024 (24 m)
srf1.45e+08 (145 M)
inductance_tol_minus_pct20 (20)
inductance_tol_plus_pct20 (20)
impedance_100mhz1020 (1.02 k)
impedance_peak2060 (2.06 k)
impedance_peak_freq1.31e+08 (131 M)
temp_min_c-40 (-40)
temp_max_c125 (125)
device_typeinductor
familyWE-LQS

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 4899 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).

PartManufacturerGradeDirectionFootprint
DFE322520FD-1R0M=P2Muratamajor_reviewmixedsmaller
SPM4030T-1R0MTDKminor_reviewunknownsmaller
SPM4030T-1R0M-HZTDKminor_reviewmixedsmaller
XFL7015-102MECCoilcraftmajor_reviewunknownone_size_larger
B82472G6102M000TDKmajor_reviewmixedone_size_larger

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.