Würth Elektronik · magnetic · case 3816
| inductance | 2.5e-06 (2.5 µ) |
|---|---|
| saturation_current | 1.25 (1.25) |
| rated_current | 1.45 (1.45) |
| dcr | 0.058 (58 m) |
| srf | 1.2e+08 (120 M) |
| device_type | inductor |
| family | WE-TPC |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 3048 scored candidates from other manufacturers (catalogue version 2705ed3e49cf9156).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| VLF4014ST-2R2M1R9 | TDK | minor_review | mixed | fits |
| VLS5030EX-2R4N-D | TDK | minor_review | upgrade | one_size_larger |
| VLCF4028T-2R7N1R8-2 | TDK | minor_review | upgrade | one_size_larger |
| VLCF5020T-2R7N2R2-3 | TDK | minor_review | upgrade | one_size_larger |
| VLCF5024T-2R7N1R5-2 | TDK | minor_review | upgrade | one_size_larger |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.