Bourns · magnetic
| inductance | 2.7e-06 (2.7 µ) |
|---|---|
| saturation_current | 1.9 (1.9) |
| saturation_percent_drop | 5 (5) |
| rated_current | 2.5 (2.5) |
| dcr | 0.033 (33 m) |
| srf | 1.2e+08 (120 M) |
| inductance_tol_minus_pct | 10 (10) |
| inductance_tol_plus_pct | 10 (10) |
| temp_min_c | -55 (-55) |
| temp_max_c | 105 (105) |
| device_type | inductor |
| family | 5300 |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 7057 scored candidates from other manufacturers (catalogue version 8e2e7e7cff3d38e6).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| 74457027 | Würth Elektronik | minor_review | mixed | unknown |
| 74456025 | Würth Elektronik | minor_review | mixed | unknown |
| SLF12575T-2R7N7R0-H | TDK | minor_review | mixed | unknown |
| 7843320270 | Würth Elektronik | major_review | mixed | unknown |
| SER1052-252MLC | Coilcraft | drop_in | unknown | unknown |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.