PCR1J390MCL1GS

Nichicon · capacitor · case 8x10

capacitance3.9e-05 (39 µ)
v_rated63 (63)
ripple_current_rms2.7 (2.7)
esr0.028 (28 m)
esr_frequency100000 (100 k)
ripple_current_frequency100000 (100 k)
capacitance_min3.12e-05 (31.2 µ)
capacitance_max4.68e-05 (46.8 µ)
temp_min_c-55 (-55)
temp_max_c125 (125)
technologyaluminum-electrolytic-polymer
familyPCR

Report a problem with this part (opens a public GitHub issue) · data quality

Substitutes

Best 5 of 177 scored candidates from other manufacturers (catalogue version 103754c4b2cacfcb).

PartManufacturerGradeDirectionFootprint
63SXV39MPanasonicminor_reviewupgradedifferent_case
875075855005Würth Elektronikmajor_reviewdowngradefits
80SXV47MPanasonicminor_reviewupgradedifferent_case
A771MN686M1JLAS018KEMETminor_reviewupgradedifferent_case
63SXV33MPanasonicminor_reviewupgradedifferent_case

Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.

Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.