Texas Instruments · analog · case WQFN
| channels | 4 (4) |
|---|---|
| input_offset_voltage | 0.007 (7 m) |
| input_bias_current | 2.5e-07 (250 n) |
| vsupply_min | 2 (2) |
| vsupply_max | 32 (32) |
| quiescent_current | 0.0002 (200 µ) |
| propagation_delay | 1.3e-06 (1.3 µ) |
| device_type | comparator |
| output_stage | openDrain |
Report a problem with this part (opens a public GitHub issue) · data quality
Best 5 of 98 scored candidates from other manufacturers (catalogue version 7745e7dd59dce573).
| Part | Manufacturer | Grade | Direction | Footprint |
|---|---|---|---|---|
| MAX993 | Maxim Integrated | minor_review | upgrade | unknown |
| LM2901HYDT | STMicroelectronics | minor_review | upgrade | different_case |
| LM139ADT | STMicroelectronics | minor_review | upgrade | different_case |
| LM139DT | STMicroelectronics | minor_review | upgrade | different_case |
| LM2901DT | STMicroelectronics | minor_review | equivalent | unknown |
Grades: drop_in, minor_review, major_review, redesign, no_substitute. “unverified” means a record is silent on that point, not that the part passed it. full cross-reference as JSON.
Values are SI base units; a spec not listed is not stated in the part's record (it is not zero). Machine access: MCP at /mcp, /llms.txt. Open catalogue — Kelvin.