{"dataVersion":"8e2e7e7cff3d38e6","mode":"details","family":"controller","part":{"mpn":"LM5175","manufacturer":"Texas Instruments","specs":{"category":"pwmController","integrated_driver":false,"integrated_fet":false,"lifecycleStatus":"production","topologies":[]},"_lineno":47,"_srcOffset":49750,"_srcLength":1671,"record":{"controller":{"manufacturerInfo":{"datasheetInfo":{"electrical":{"deadTime":{"maximum":5.5e-08,"minimum":2e-09},"referenceVoltage":{"maximum":0.812,"minimum":0.788},"switchingFrequencyMax":220000.0,"switchingFrequencyMin":180000.0},"function":{"category":"pwmController"},"part":{"deviceType":"controller","partNumber":"LM5175"},"pins":[{"function":"enable","name":"EN/UVLO","pin":"1"},{"function":"vin","name":"VIN","pin":"2"},{"function":"other","name":"VISNS","pin":"3"},{"function":"modeSelect","name":"MODE","pin":"4"},{"function":"frequencySet","name":"DITH","pin":"5"},{"function":"other","name":"RT/SYNC","pin":"6"},{"function":"compensation","name":"SLOPE","pin":"7"},{"function":"softStart","name":"SS","pin":"8"},{"function":"compensation","name":"COMP","pin":"9"},{"function":"ground","name":"AGND","pin":"10"},{"function":"feedback","name":"FB","pin":"11"},{"function":"other","name":"VOSNS","pin":"12"},{"function":"currentSense","name":"CSG","pin":"15"},{"function":"currentSense","name":"CS","pin":"16"},{"function":"powerGood","name":"PGOOD","pin":"17"},{"function":"pgnd","name":"PGND","pin":"22"},{"function":"vcc","name":"VCC","pin":"23"},{"function":"vbias","name":"BIAS","pin":"24"}],"provenance":[{"retrievedDate":"2026-08-01","source":"manufacturerParametric"},{"fields":["datasheetInfo.pins"],"retrievedDate":"2026-08-02","source":"manufacturerDatasheet"}]},"datasheetUrl":"https://www.ti.com/lit/ds/symlink/lm5175.pdf","name":"Texas Instruments","reference":"LM5175","status":"production"}}},"permalink":"https://kelvin.openconverters.com/part/controller/LM5175?manufacturer=Texas%20Instruments","_dataVersion":"8e2e7e7cff3d38e6","sourceUrl":"https://www.ti.com/lit/ds/symlink/lm5175.pdf","reportUrl":"https://github.com/OpenConverters/Kelvin/issues/new?labels=data-quality&title=Wrong+data%3A+LM5175+%28controller%29&body=Part%3A+https%3A%2F%2Fkelvin.openconverters.com%2Fpart%2Fcontroller%2FLM5175%3Fmanufacturer%3DTexas%2520Instruments%0ACatalogue+version%3A+8e2e7e7cff3d38e6%0A%0AWhat+is+wrong+%28the+field%2C+the+value+Kelvin+shows%2C+the+value+on+the+datasheet%2C+and+the+datasheet+page+or+link%29%3A%0A%0A"}}